The Canon TTL Flash Metering System

Posted on November 22, 2008 @ 10:45 pm

Metering for ambient lighting conditions and flash metering has totally different requirement. The metering for ambient lighting condition is done before the shutter of the camera is opened. In the Canon EOS camera, ambient light metering is done when you press the shutter button halfway down. Flash Pulse metering however is done when the shutter button is press fully down. There are two ways to meter for flash pulse automatically. One way is by measuring the flash pulse as it is being released. The other way is to do a pre-flash test. This is achieved by a low powered test pulse of a calculated brightness before the shutter opens.

These are the two methods of flash metering which Canon uses for their system. The first method as described above is the Through The Lens (TTL) system. This method was first introduced by Canon during the 1980s with the introduction of the T90 model. The system was later adopted by the EOS range of Cameras as a standard feature. This makes the T90 as the only non EOS Camera which uses the TTL flash metering system.

The TTL system works by calculating the amount of light which is reflected off the subject into the camera after the flash light is emitted by the flash unit. It actually measures the light which is reflected of the film in real time and this done by using an OTF (Off The Film) sensor. When enough light has entered the OTF sensor, the flash will be deactivated. Due to the fact that the Canon EOS Digital cameras do not use films, the Digital range of Canon cameras does not support the TTL system.

The sequence of operation of the TTL system is as follows;

1. When the shutter button is depressed halfway the ambient light metering operation runs its course. The shutter speed and aperture is set by the camera or the user depending on what mode is used. For example; P mode, AV mode or M Mode.

2. Only when the shutter button is depressed all the way, the internal mirror is turn up and exposes the film. Power is then sent to the flash unit which will emit a flash light to illuminate the scene. The length of the flash pulse is determined by the OTF sensor in the camera which is metered for normal operational conditions. If the picture is taken under bright lighting conditions, the auto fill reduction will take effect and reduce the illumination of the Flash.

3. After the foreground is adequately illuminated, the power to the flash unit is cut off which in turn kills the flash light. During this time the shutter is opened until it has runs it course. Once that sequence has been completed, the mirror of the camera returns to its original position. Cameras which have a warning light to confirm the success of the flash exposure operations will glow to indicate its success of the metering operations.

It is also important to note that as the OTF sensor reflects the amount of light of the film, the composition of the film itself will also affect the amount that is reflected off. But as all camera are calibrated to work with normal film this will not become an issues except with special films like slide films which has different level of tolerances.